view all product images
|
BX43
World-famous optics and operating efficiency for a wide range of clinical applications
The new BX43 upright microscope replaces the BX41 with enhanced user operation and improved optical versatility. The new light intensity management system, binocular and trinocular observation tubes, and coded nose pieces for auto calibration.Olympus continues the history of providing outstanding value in a clinical microscope.
The BX43 supports brightfield, phase contrast, simple polarized light, and darkfield observation. New LED illumination assures a constant colour temperature for consistent and accurate color imaging.
Flexible system format supports a wide-range of observation methods
- New binocular and trinocular observation heads enhance the ergonomics and operation of a BX43 microscope. Choose between tilting and traditional configurations.
- The new light intensity management feature, with the new revolving encoded objective nosepieces, controls light intensity as observation magnification changes.
- The new LED light source offers superb colour reproduction from purple to cyan to red, and long lifespan.
- Get digital images in a snap! The new hand switch for the Olympus DP21 digital camera can be easily mounted within a finger’s reach of the focus knob, allowing the operator to snap a digital image without disrupting observation.
- New U-LC condenser achieves even illumination of specimens for observation from 2x to 100x dry. An assortment of other condensers allow you to perform a wide range of contrast techniques such as Nomarski (DIC), polarization for Gout analysis, phase contrast, and darkfield observation.
Ergonomic design for efficiency and comfort
- Updated Y-shaped frame brings user controls forward for ease of access, efficiency and enhanced operator comfort.
- The new tilting, telescoping/ lifting binocular observation tube offers unsurpassed comfort in viewing position. The new U-TTLBI binocular head tilts from 0-27°, extends an incredible 55mm, and lifts 45mm to accommodate different operators and reduce fatigue during use.
- The new colour-balanced LED with light intensity management system diminishes eye fatigue and the strain of repetitive adjustments.
Supports a wide range of observation methods
| |
|
|
Brightfield
UIS optics and a diverse line of condensers support clear brightfield images with superb resolution and flatness at all magnifications.
|
|

Brightfield
|
Phase Contrast
Universal phase-contrast objectives have high transmission, producing well-balanced images with high contrast.
|
|

asbestos body
|
Simple Polarized Light
Various compensators make it possible to observe a wide range of retardation. Also available is a condenser exclusively for polarization observation, revolving nosepiece, rotating stage, objectives, simple polarising
attachment and analyzer for gout inspection.
|
|

Urate Crystals
|
Darkfield
Two darkfield condensers are provided: dry condenser(U-DCD) with magnification range from 10× to 100× and oil immersion condenser(U-DCW) with magnification range from 20× to 100× for darkfield contrast. Universal condensers also allow simple darkfield contrast
|
|

Water flea
|
Special features for enhanced operator comfort
Observation Tubes Lineup Caters to Your Every Need
A newly-designed tilting, telescopic, lifting binocular tube, U-TTLBI extends and tilts with simple adjustments for optimum posture. The design allows long hours of observation in comfort, regardless of physique.
Tilting Trinocluar Observation Tube
Tilting trinocular tube/ U-TTR-2 enables to accommodate any operator posture with the slant angle of binocular from 5 through 35 degrees. In addition, Olympus offers versatile types of tubes.
|
|
 |
Tilting, Telescopic, Lifting Binocular Tube ( three movable parts )
|
|
Tilting, Lifting, Telescopic Observation Tube
A newly-designed tilting, telescopic, lifting binocular tube, U-TTLBI extends and tilts with simple adjustments for optimum posture. The design allows long hours of observation in comfort, regardless of physique. The Olympus BX43/BX46/BX53 series defines a revolutionary new standard in laboratory and clinical microscopy. Ergonomic design can provide enhancedoperator comfort during long hours of use, with an intuitive control layout for fast, efficient observation and imaging.
|
|
 |
 Tilting, telescopic, lifting binocular tube ( three movable parts )
Light Intensity Manager
The feature functions with the BX43-5RES, a coded 5-position nosepiece eliminating light intensity adjustments when switching magnifications. This feature functions with the BX43-5RES, a coded 5-position nosepiece for BX43, eliminating light intensity adjustments when switching magnifications. The long-life LED ensures uniform brightness with easy maintenance.
|
|

Light Intensity Manager
|
Low Magnification Condencer, U-LC to Improve Efficiency
Changing objective magnification from 2× to 100× (dry) is now possible without having to change the condenser or move the top lens.
 Consecutive observation
Optimal LED lighting and UIS2 optics
Optimal LED Lighting for Brightfield
Olympus white LED with high color rendering index has wavelength characteristics close to those of halogen, realizing color reproduction equivalent to halogen lamps. LED lighting is dimmable with a constant color temperature, preventing filter adjustments.
|

Spectral Characters (LED and conventional lights)
|
UIS2 Optics Delivers Image Clarity.
The UIS2 objectives and eyepieces combination delivers image clarity so that the white of the background stands out with the stained specimen more.
|

Observation image of UIS2
|
A Line-up of Microscope Digital Cameras
The digital camera suitable for Clinico-Pathological l Conference performs a live-speed display and image capturing without PC. A line up of Olympus microscope digital cameras also includes a high-definition, high-color-reproduction model for further applications.
|

BX43 & DP21
|
Hand Switch for Image Capture
The U-HSEXP hand switch for exposure attaches easily on the microscope, and allows the operator to capture an image without having to take his/her eyes away from the specimen. The exposure switch is located close to the focus handle creating minimal movement during operation.
|

Hand Switch
|
| Microscope frame | Optical system |
UIS2 optical system |
| Focus |
Vertical stage movement: 25 mm stage stroke with coarse adjustment limit stopper, Torque adjustment for coarse adjustment knobs, Stage mounting position variable, High sensitivity fine focusing knob (minimum adjustment gradations: 1 µm) |
| Illuminator |
Built-in Koehler illumination for transmitted light, light intensity manager switch High color reproductivity LED light source, 6 V 30 W halogen bulb (pre-centered) |
| Revolving nosepiece |
Interchangeable reversed quintuple/coded quintuple/sextuple/septuple/coded septuple nosepiece |
| Observation tube | Widefield (F.N. 22) |
• Widefield tilting, telescopic and lifting binocular • Widefield tilting trinocular • Widefield trinocular • Widefield erect image trinocular • Widefield tilting binocular • Widefield ergo binocular • Widefield binocular |
| Super widefield (F.N. 26.5) |
• Super widefield trinocular • Super widefield erect image trinocular |
| Stage |
Ceramic-coated coaxial stage with left or right hand low drive control: with rotating mechanism and torque adjustment mechanism, optional rubber grips available (Non stick grooved coaxial, plain, rotatable stages are also available) |
| Condenser |
• Abbe (N.A. 1.1), for 4×-100× • Swing out Achromatic (N.A. 0.9), for 1.25×-100× (swing-out: 1.25×-4×) • Achromatic Aplanatic (N.A. 1.4), for 10×-100× • Phase contrast, darkfield (N.A. 1.1), [phase contrast: for 10×-100×, darkfield: for 10×-100× (up to N.A. 0.80)] • Universal (N.A. 0.9), for 1.25×-100× [swing-out: 1.25×-4×, with oil top lens:(N.A. 1.4)] • Low (N.A. 0.75), for 2×-100× (Dry) • Ultra low (N.A. 0.16), for 1.25×-4× • Darkfield dry (N.A. 0.8-0.92), for 10×-100× • Darkfield oil (N.A. 1.20-1.40), for 10×-100× |
| Operating environment |
• Indoor use • Ambient temperature : 5 ° to 40 °C (41 ° to 104 °F) • Maximum relative humidity : 80 % for temperatures up to 31° C (88 °F), decreasing linearly through 70 % at 34 °C(93 °F), 60 % at 37 °C (99 °F), to 50 % relative humidity at 40 °C (104 °F) • Supply voltage fluctuations : Not to exceed ±10 % of the normal voltage |
BX43 dimensions (unit: mm)

|