VISERA CLV-S40
CLV-S40 Xenon Light Source - It is a superior lighting for any endoscopy site
Ideal for Endoscopic TV oberservation connectable with conventional telescopes, fibrescopes, Visera videoscopes and OES fibrescope. Adaptable to all endoscopic procedures: The powerful and convenient CLV-S40 makes endoscopic procedures easier then ever.
Powerful & Long-Life 300-Watt Xenon Lamp
This high-quality xenon lamp provides an illumination which is ideal for endoscopy, allowing observation in deep sites or advanced techniques. Plus, it can be used continuously for 500 hours (in intermittent use, lamp life time may differ slightly).
Automatic Brightness Control
When the CLV-S40 is connected via a light guide cable to video systems such as the Visera system; brightness can be automatically adjusted, saving your time and energy.
Standby
Illumination can be set to standby using a switch on the front panel or a remote switch on the camera head.
Intensity-Mode Memory
With Intensity-Mode Memory, when the CLV-S40 is turned off in the high intensity mode, it will still be in that mode when turned back on. This is also true for the normal intensity mode.
Easy-to-See Front Panel
You can easily adjust brightness and power with buttons and switches on the front panel.
| Specification |
System |
|
| Power Requirements |
Voltage (AC) (see electrical ranging plate) |
120V, 220V, 230V, 240V |
| Frequency |
50/60 Hz |
| Input |
6A (120V), 3A (220V, 230V, 240V) |
| VoltageFluctuation |
|
| Size |
Dimensions |
295 (W) x 125 (H) x 395,4 (D) mm (maximum) |
| Weight |
12 kg |
| Illumination |
Lamp |
Xenon short arc lamp (ozone-free) 300W |
| Lamp Life |
Approx. 500 hours in continious use |
| (In intermittent use, lamp life may differ slightly) |
| Ignition |
Switch regulator |
| Brightness Adjustment |
Light-path diaphragm control |
| Cooling |
Forced-air cooling |
| Emergency lamp |
Halogen lamp (withour mirror) 24V 150W |
| Emergency Lamp Life |
Approx. 500 hours in continious use |
| (In intermittent use, lamp life may differ slightly) |
| Visual Oberservation |
Control Method (automatic) |
Servo-diaphragm |
| Video System |
Automatic Sensitivity (automatic) |
17 steps |
| Front Panel |
Emergency Lamp Indicator |
Indicates that the emergency lamp is operating and flashes when the emergency lamp is broken |
| Intensity-Mode Memory Indicator |
|
Indicates that Intensity-Mode is selected |
| Standby-Mode Indicator |
|
Indicates that Standby-Mode is selected |
| Setting Retention |
|
Selected settings are retained when the light source is switched off |