LA-201 - EndoLifter: Single use grasping forceps
|
• Acting like an extra hand to provide optimal lesion countertraction EndoLifter supports gastric ESD
• Unique structure: grasping forceps connected to a distal attachment
• Makes it easy to slip the endoscope tip into the submucosa
• Ensures a broader view by lifting up the tissue
• Facilitates visual confirmation of blood vessels, supporting preventive haemostasis and making it easier to cope with bleeding
• Supports effective dissection by providing the necessary amount of tension to the mucosa
• Specially designed for grasping and lifting of the tissue
• Specially designed jaws have enough power to maintain but do not grasp the tissue too strongly
• Two locks prevent inadvertent movement
NOTE: This device is intended to be used within the stomach only
• Working length: 1950mm
• Max outer diameter: 13.85mm
• Opening width of grasping forceps: 8mm |
|
|
LA-202 - EndoLifter: Single use grasping forceps
|
• Acting like an extra hand to provide optimal lesion countertraction EndoLifter supports gastric ESD
• Unique structure: grasping forceps connected to a distal attachment
• Makes it easy to slip the endoscope tip into the submucosa
• Ensures a broader view by lifting up the tissue
• Facilitates visual confirmation of blood vessels, supporting preventive haemostasis and making it easier to cope with bleeding
• Supports effective dissection by providing the necessary amount of tension to the mucosa
• Specially designed for grasping and lifting of the tissue
• Specially designed jaws have enough power to maintain but do not grasp the tissue too strongly
• Two locks prevent inadvertent movement
NOTE: This device is intended to be used within the stomach only
• Working length: 1950mm
• Max outer diameter: 14.95mm
• Opening width of grasping forceps: 8mm |
|
|
KD-611L - IT Knife2: Single use electrosurgical knife
|
• For Upper GI
• Unique electrode design on the proximal side of the tip minimises invasiveness whilst maximising cutting versatility
• Ceramic tip for increased assurance
• The electrode incorporated on the proximal side of the ceramic tip features a unique new design that provides exceptional cutting performance
• This unique electrode design makes it possible to perform lateral cutting from a vertical approach
• Working length: 1650mm
• Minimum working channel: 2.8mm |
|
|
KD-620LR - Hook Knife: Single use electrosurgical knife
|
• For Upper GI
• Distal L-Shaped hook and rotation function for incision and dissection in longitudinal and lateral directions
• Turn and lock design
• The knife is used to hook tissue and draw it away from the mucosa while diathermy is applied to cut. This drawing method minimises the risk of perforation.
• Working length: 1650mm
• Minimum working channel: 2.8mm
• Features: rotatable |
|
|
KD-620QR - Hook Knife: Single use electrosurgical knife
|
• For Lower GI
• Distal L-Shaped hook and rotation function for incision and dissection in longitudinal and lateral directions
• Turn and lock design
• The knife is used to hook tissue and draw it away from the mucosa while diathermy is applied to cut. This drawing method minimises the risk of perforation.
• Working length: 1950mm
• Minimum working channel: 2.8mm
• Features: rotatable |
|
|
KD-620UR - Hook Knife: Single use electrosurgical knife
|
• For Lower GI
• Distal L-Shaped hook and rotation function for incision and dissection in longitudinal and lateral directions
• Turn and lock design
• The knife is used to hook tissue and draw it away from the mucosa while diathermy is applied to cut. This drawing method minimises the risk of perforation.
• Working length: 2300mm
• Minimum working channel: 2.8mm
• Features: rotatable |
|
|
KD-630L - Flex Knife: Single use electrosurgical knife
|
• For Upper GI
• Smart sheath design combining a slim sheath with flexible stranded wire makes the knife pliable enough to enable incision and dissection in all directions
• Loop design cutting section at the tip of the knife contacts a larger area
• Buffer collar functions as a cushion and stopper
• Adjustable length - suitable for marking, incision and dissection
• Working length: 1650mm
• Minimum working channel: 2.8mm |
|
|
KD-650L - Dual Knife: Single use electrosurgical knife
|
• For Upper GI
• Knife length can be fixed at either of the two positions - retracted or extended - for reliable, confident cutting
• Knob-shaped needle knife tip makes the needle less likely to slip, simplifies marking and haemostatsis
• Dome shaped ceramic sheath tip ensures that it is safe even when the tip is brought in to contact with tissue
• Slim sheath with just the right degree of rigidity makes it easier to hook the needle on the tissue
• Working length: 1650mm
• Minimum working channel: 2.8mm |
|
|
KD-650Q - Dual Knife: Single use electrosurgical knife
|
• For Lower GI
• Knife length can be fixed at either of the two positions - retracted or extended - for reliable, confident cutting
• Knob-shaped needle knife tip makes the needle less likely to slip, simplifies marking and haemostatsis
• Dome shaped ceramic sheath tip ensures that it is safe even when the tip is brought in to contact with tissue
• Slim sheath with just the right degree of rigidity makes it easier to hook the needle on the tissue
• Working length: 1950mm
• Minimum working channel: 2.8mm |
|
|
KD-650U - Dual Knife: Single use electrosurgical knife
|
• For Lower GI
• Knife length can be fixed at either of the two positions - retracted or extended - for reliable, confident cutting
• Knob-shaped needle knife tip makes the needle less likely to slip, simplifies marking and haemostatsis
• Dome shaped ceramic sheath tip ensures that it is safe even when the tip is brought in to contact with tissue
• Slim sheath with just the right degree of rigidity makes it easier to hook the needle on the tissue
• Working length: 2300mm
• Minimum working channel: 2.8mm |
|
|
KD-640L - Triangle Tip Knife: Single use electrosurgical knife
|
• For Upper GI
• Triangle tip at the distal end for all procedures from marking to incision and dissection
• Unique triangle tip design enables to snag and hook tissue more easily
• Cutting while coagulating
• Versatile application enables to use the knife at any step of the ESD procedure
• Working length: 1650mm
• Minimum working channel: 2.8mm |
|
|
KD-640L - Triangle Tip Knife: Single use electrosurgical knife
|
• For Upper GI
• Triangle tip at the distal end for all procedures from marking to incision and dissection
• Unique triangle tip design enables to snag and hook tissue more easily
• Cutting while coagulating
• Versatile application enables to use the knife at any step of the ESD procedure
• Working length: 1650mm
• Minimum working channel: 2.8mm |
|
|
FD-410LR - Disposable Coagrasper
|
• For Upper GI
• Unique hemostatic grasping device
• Innovative design combines the mechanical tamponade benefits of a hemoclip with the coagulation benefits of a thermal probe
• Designed to cauterize, coagulate and stop bleeding in the GI tract during ESD
• Rotation feature allows approach from any angle
• Tapered tip and anti-slip construction provides more secure grasping of bleeding point
• Monopolar
• Working length: 1650mm
• Minimum working channel: 2.8mm
• Opening width of distal cups: 5mm |
|
|
FD-411UR - Disposable Coagrasper
|
• For Lower GI
• Unique hemostatic grasping device
• Innovative design combines the mechanical tamponade benefits of a hemoclip with the coagulation benefits of a thermal probe
• Designed to cauterize, coagulate and stop bleeding in the GI tract during ESD
• Rotation feature allows approach from any angle
• Anti-slip construction provides more secure grasping of bleeding point
• Monopolar
• Working length: 2300mm
• Minimum working channel: 3.2mm
• Opening width of distal cups: 4mm |
|
|
ESG-100 - Electrosurgical Generator 220-240V
|
A new dimension in electrosurgery
• Olympus ESG-100 incorporates technical features that provide excellent effectiveness and highest safety in cutting and coagulation during endoscopic procedures
• Olympus‘ Rapid Spark Technology features High Power Cut Support (HPCS) to achieve immediate spark ignition and Fast Spark Monitor (FSM) to optimise cutting procedures in various tissue structures
The results: reduced leakage currents, reproducible tissue effects and enhanced protection of EndoTherapy instruments
• Olympus’ Versatile Coagulation Technology enables fast and effective desiccation as well as soft and deep tissue coagulation in monopolar and bipolar modes
The results: controlled haemostasis as well as effective coagulation of larger tissue volumes with end-of-procedure detection and acoustic feedback
• Cutting modes to meet your needs - monopolar and bipolar continuous cutting modes with low, medium or high thermal effects in tissue
• Coagulation modes to meet your needs - One monopolar soft coagulation mode with minimal sticking for controlled desiccation. Two monopolar forced coagulation modes for fast and effective haemostasis with low and high power capabilities
• Contains unit and footswitch |
|
|
AFU-100 Peristalic Water Pump
|
• Olympus ESG-100 has been designed to work together with the new peristaltic pump AFU-100
• With its maximum flow of 600 ml/min this roller pump is useful to clean the treatment site through the endoscopes’ instrument channel and to flush through EndoTherapy instruments
• The AFU-100 offers fast tube insertion, three programmable pre-set flow rates, as well as a variable flow rate, and follows the easy-to-use concept of the ESG-100
• Flow Rate 10…270ml/min (Pump Tube ID3.2mm - 15 pieces/box, sterile single use, length: 0,5m)
and 20…600ml/min (Pump Tube ID4.8mm - 15 pieces/box, sterile single use, length: 0,5m)
• Contains unit and connection cable |
|
First Glass Modular ENDOALPHA OR in Australia launched at John Flynn
NBI Atlas
|